Precast Manholes, JRC-4 / JRC-12 / JRC-14 & Utility Chambers UAE

Precast manholes, Etisalat/Du JRC-4, JRC-12, and JRC-14 telecom jointing chambers, catch basins, and utility chambers for UAE networks.

Indicative price AED 3500 – 18000 Subject to specification and quantity. Final quote on request.

Technical Support
UAE Delivery
System JRC-4, JRC-12, JRC-14, Drainage & CB
Telecom JRC JRC-4 / JRC-12 / JRC-14 (Etisalat / Du)
Concrete C35/45 to C40/50 SRC
Openings Top access / side knockout / duct bank

Product Description

Precast Manholes, JRC-4 / JRC-12 / JRC-14 & Utility Chambers UAE

PRECAST UAE manufactures precast concrete manholes, JRC-4, JRC-12, and JRC-14 telecom jointing chambers, catch basins, inspection chambers, and utility chambers for drainage, Etisalat (e&) and Du telecom corridors, DEWA electrical networks, water lines, and infrastructure packages across the UAE. Units are factory-cast in C40/50 Sulphate Resisting Cement (SRC) with exact openings, reinforcement, lifting anchors, and full QA/QC traceability.

JRC-4, JRC-12 & JRC-14 Telecom Jointing Chambers

We produce heavy-duty precast concrete JRC (Jointing and Resource Chamber) manholes aligned with UAE outside-plant (OSP) telecom network standards for Etisalat and Du infrastructure packages:

  • JRC-4 Telecom Manhole: Compact branch and property lead-in jointing chamber (~915–1115 × 445–660 × 750–925 mm internal), configured for Carriageway Type No. 4 (EN 124 D400) frames and lower side duct entries.
  • JRC-12 Telecom Manhole: Secondary distribution jointing chamber (~1220 × 675–980 × 900–1350 mm internal), configured for Carriageway Type No. 2 double-triangular D400 frames, cable bearer fixings, and multi-way uPVC duct banks.
  • JRC-14 Telecom Backbone Manhole: Large main-line trunk jointing chamber (~2585 × 1000–1120 × 1575 mm internal), cast for Carriageway Type No. 3 multi-part D400 covers with heavy rebar cages, pulling-in irons, cable rack inserts, and sump/step irons.

(Exact dimensions, wall thickness, duct knockouts, and cover rebate sizes follow your project’s approved authority OSP drawing.)

Full Utility & Drainage Chamber Range

  • Drainage Manholes: Inspection chambers for stormwater and site drainage networks (BS EN 1917).
  • Catch Basins (CB Units): Square or rectangular precast chamber bodies with broad concrete top rims, recessed square access openings, and formed lower side knockouts.
  • Electrical Chambers: Cable access and pulling chambers for DEWA/ADDC LV, HV, and site power corridors.
  • Valve & Water Chambers: Access boxes for stop valves, meters, and irrigation network service points.

Typical Technical Range

Specification Value / Description
Telecom Series JRC-4 / JRC-12 / JRC-14 (OSP Submittal Compliant)
Other Chambers Drainage Manholes / Square Catch Basins / Electrical / Valve
Wall Thickness 150 mm to 250 mm (per depth & structural load)
Concrete Grade C35/45 to C40/50 Sulphate Resisting Cement (SRC)
Openings & Embeds Duct knockouts, bellmouths, pipe sleeves, pulling-in irons
Cover Loading Pedestrian A15 up to EN 124 D400 Heavy Carriageway
Documentation Shop drawings + Concrete cube / steel QA/QC package

Any removable cast-iron, composite, or concrete cover & frame set placed above the chamber should be specified as its own BOQ item.

Why Precast Chambers Beat Site Casting

Precast JRC and utility chambers eliminate trench shuttering, wet concrete pours, and multi-day curing delays on live roads. Chambers are cast in parallel with excavation and crane-installed in sequence so trenches backfill and reopen rapidly.

What To Send For Quotation

Send your chamber list (JRC-4, JRC-12, JRC-14, catch basins, or drainage drawings), opening schedule, EN 124 load class, quantities, delivery location, and target dates via our contact page.

Technical Specifications

System JRC-4, JRC-12, JRC-14, Drainage & CB
Telecom JRC JRC-4 / JRC-12 / JRC-14 (Etisalat / Du)
Concrete C35/45 to C40/50 SRC
Openings Top access / side knockout / duct bank
Design Loading BS EN 124 D400 / Approved Design
Documentation Shop drawings + QA/QC

Frequently Asked Questions

Do you manufacture JRC-4, JRC-12, and JRC-14 telecom manholes?

Yes. PRECAST UAE manufactures Etisalat (e&) and Du style precast reinforced concrete JRC-4, JRC-12, and JRC-14 Jointing & Resource Chambers complete with duct entry knockouts, pulling-in irons, cable bearer inserts, and EN 124 D400 cover frame rebates.

Do you manufacture precast drainage manholes and catch basins?

Yes. Alongside telecom JRC chambers, we cast drainage manholes, square CB-type catch basins, DEWA electrical chambers, and valve boxes with recessed top openings, side pipe sleeves, and QA/QC documentation to approved drawings.

What are the standard internal sizes for JRC-4, JRC-12, and JRC-14?

Typical internal dimensions run roughly 915-1115 x 445-660 x 750-925 mm for JRC-4 (Carriageway Type 4), 1220 x 675-980 x 900-1350 mm for JRC-12 (Carriageway Type 2), and 2585 x 1000-1120 x 1575 mm for JRC-14 (Carriageway Type 3), produced to your approved OSP submittal drawing.

Which utilities and load ratings do you support?

Chambers cover Etisalat/Du telecom corridors, DM/ADM stormwater and foul drainage, DEWA LV/HV electrical networks, and water/irrigation valves, engineered for A15 pedestrian up to EN 124 D400 heavy carriageway loads.

What do you need to quote manholes or JRC chambers?

Send the chamber type (e.g., JRC-4, JRC-12, JRC-14, CB, or drainage MH) or approved drawings, cover load class, duct/pipe opening schedule, quantities, and delivery Emirate.

Technical Configurations

Code Type Dimensions (LxHxW) Weight (approx) Hole Size Concrete Strength Reinforcement Common Applications
JRC-4 Etisalat / Telecom Jointing Chamber JRC-4 915-1115 x 445-660 x 750-925 mm (Int.) 1,150 - 1,450 kg Type 4 Cover Frame (EN 124 D400) + Duct Knockouts 40 MPa (C40/50 SRC) T12/T16 RCC cage + pulling-in irons Branch telecom ducts, FTTx distribution, property lead-ins
JRC-12 Etisalat / Telecom Jointing Chamber JRC-12 1220 x 675-980 x 900-1350 mm (Int.) 2,100 - 2,650 kg Type 2 Double-Triangular D400 + Side Entries 40 MPa (C40/50 SRC) Double RCC mesh + cable bearer inserts Secondary telecom corridors, road crossings, junction nodes
JRC-14 Etisalat / Telecom Backbone Chamber JRC-14 2585 x 1000-1120 x 1575 mm (Int.) 5,200 - 6,800 kg Type 3 Multi-Part D400 + Multi-Way Duct Bank 40 MPa (C40/50 SRC) Heavy T16 structural cage + sump + step irons Primary fibre backbone routes, major highway OSP telecom junctions
Code Type Dimensions (LxHxW) Weight (approx) Hole Size Concrete Strength Reinforcement Common Applications
CB-SQ Square Catch Basin / Inspection Chamber 600x600 to 1500x1500 mm (To Drawing) 900 - 3,200 kg Recessed Top Access + Side Knockouts 35 - 40 MPa (C35/45 to C40/50 SRC) RCC cage to consultant structural drawing Stormwater catch basins, road gullies, yard drainage
DM-DRN DM / ADM Drainage Manhole Chamber 1000-1500 mm Dia. or Rectangular (To Drawing) 1,800 - 4,800 kg 600mm Clear Top Opening + Formed Pipe Sleeves 40 MPa (C40/50 SRC + Internal Coating) BS EN 1917 RCC + GRP benching option Municipal stormwater & foul sewer networks, D400 carriageways
DEWA-ELC DEWA / ADDC Electrical Cable Chamber 900x900 to 2000x1500 mm (To Drawing) 1,600 - 4,500 kg uPVC Bellmouth Duct Entries + Earth Point 40 MPa (C40/50 SRC) Double mesh RCC + hot-dip galvanized inserts LV/HV power cable pulling pits, transformer & valve chambers

Dubai South Office

Business Centre, Floor 3, Building A3, Dubai South, Dubai

Hours: Mon–Fri 8:00 AM – 5:30 PM

Sharjah Factory

Sharjah Industrial Area, Sharjah

Hours: Mon–Sat 7:00 AM – 6:00 PM

24h Quote
Fast Response
UAE Delivery
Nationwide
Factory Direct
Best Value

Talk to our team

We're here to help with your project

Sales Support: +971 54-171-3700 General Inquiries:

Request a Project Quote

Share your requirements and we'll get back to you within 24 hours.

1 Contact
2 Project
3 Details
Your information is secure and will not be shared.
Success! Your inquiry has been received. Our team will contact you shortly.
Error! Please check your connection and try again.
Call WhatsApp Email